Industrial Hoist: DC1600


INDUSTRIAL HOIST DC1600

The DC1600 hoist combines a powerful permanent magnet DC motor with robust sealing and our proven 3-stage all metal geartrain. Permanent grease lubrication means years of trouble free service. All WARN hoists incorporate an automatic mechanical brake that holds full rated load. The durable powder coated finish stands up to the elements and looks great. The DC1600 hoist is built on WARN's robust large frame design with a cast aluminum drum to provide plenty of wire rope capacity. Controls and accessories available separately.

DC1600 SPECS/PART NUMBERS
Part Number: 33503 12V
Part Number: 85159 24V
Rated Capacity: 1600 lbf (726 kgf)
Drum Barrel Diameter: 4.25 in (108 mm)
Drum Flange Diameter: 8.25 in (210mm)
Distance Between Flanges: 3.79 in (96mm)
Recommended Maximum Wire Rope Diameter: 1/4 in (6.4 mm)
Recommended Wire Rope Breaking Strength: 7000 lbf (3175 kgf)
Approximate Shipping Weight: 50 lbs. (22.7 kg)
Duty Cycle (intermittent per SAE J706 section 6.2): N/A ft (N/A m)
Mounting Bolt Torque: 35-40 ft*lbf (47 - 54 N*m)
Maximum Layers of Wire Rope: 5
Gear Reduction: 261
Brake Type: Automatic Cone
Contactor/Remote Type: Not Included
Standards Compliance: 
CE Machinery Directive 98/37/EC and 2006/42/EC
CE Electromagnetic Compatibility 2004/108/EC
ASME B30.5

ACCESSORIES
Control Pack-12V: PN 40709
Control Pack-24V: PN 63752
Contactor Only-12V (Standard bracket): PN 34440
Contactor Only-24V (Standard bracket): PN 34968
Contactor Only-12V (w/ bracket for cover): PN 34973
Contactor Only-24V (w/ bracket for cover): PN 34974
Contactor Cover (with remote plug): PN 36648
Contactor Cover (no plug): PN 35169
Remote Control Only: PN 88528

PERFORMANCE BY LAYER - 12V
Drum LayerLine Load *No Load Line SpeedDrum Capacity
lbfkgfkNft/minm/minftm
116007267.114.74.5164.9
214406536.416.35.03410.4
313125955.818.05.55316.2
412005445.319.66.07422.6
511045014.921.26.59729.6
* Never exceed the Rated Capacity. Installation of a Rated Capacity Limiter is recommended.

FIRST LAYER PERFORMANCE - 12V
Line LoadCurrent Draw Line SpeedDuty Cycle
lbfkgfAmpsft/minm/minmin/10min
001314.74.5Continuous
4001813113.84.2Continuous
8003635313.44.15.8
12005447412.93.93.6
16007269512.53.82.6

PERFORMANCE BY LAYER - 24V
Drum LayerLine Load *No Load Line SpeedDrum Capacity
lbfkgfkNft/minm/minftm
116007267.114.34.4164.9
214406536.415.94.83410.4
313125955.817.55.35316.2
412005445.319.15.87422.6
511045014.920.66.39729.6
* Never exceed the Rated Capacity. Installation of a Rated Capacity Limiter is recommended.

FIRST LAYER PERFORMANCE - 24V
Line LoadCurrent Draw Line SpeedDuty Cycle
lbfkgfAmpsft/minm/minmin/10min
00614.34.4Continuous
4001811514.04.3Continuous
8003632313.84.2Continuous
12005443313.34.16.8
16007264313.04.04.6