Industrial Hoists: DC2000 Mid Frame


INDUSTRIAL HOIST DC2000 MID FRAME

The DC2000 hoist combines a powerful permanent magnet DC motor with robust sealing and our proven 3-stage all metal geartrain. Permanent grease lubrication means years of trouble free service. All WARN hoists incorporate an automatic mechanical brake that holds full rated load. The durable powder coated finish stands up to the elements and looks great. The DC2000 hoist is built on a compact midsize framed with integrated tie bars that's easy to install. Controls and accessories available separately.

DC2000 SPECS/PART NUMBERS
Part Number: 63899 12V
Part Number: 85190 24V
Rated Capacity: 2000 lbf (907 kgf)
Drum Barrel Diameter: 4.25 in (108 mm)
Drum Flange Diameter: 6.25 in (159 mm)
Distance Between Flanges: 4.5 in (114 mm)
Recommended Maximum Wire Rope Diameter: 1/4 in (6.4 mm)
Recommended Wire Rope Breaking Strength: 7000 lbf (3175 kgf)
Approximate Shipping Weight: 40 lbs. (18.1 kg)
Duty Cycle (intermittent per SAE J706 section 6.2): N/A ft (N/A m)
Mounting Bolt Torque: 32-34 ft*lbf (43 - 46 N*m)
Maximum Layers of Wire Rope: 2
Gear Reduction: 261
Brake Type: Automatic Cone
Contactor/Remote Type: Not Included
Standards Compliance: 
CE Machinery Directive 98/37/EC and 2006/42/EC
CE Electromagnetic Compatibility 2004/108/EC
ASME B30.5

ACCESSORIES
Control Pack-12V: PN 40709
Control Pack-24V: PN 63752
Contactor Only-12V (Standard bracket): PN 34440
Contactor Only-24V (Standard bracket): PN 34968
Contactor Only-12V (w/ bracket for cover): PN 34973
Contactor Only-24V (w/ bracket for cover): PN 34974
Contactor Cover (with remote plug): PN 36648
Contactor Cover (no plug): PN 35169
Remote Control Only: PN 88528

PERFORMANCE BY LAYER - 12V
Drum LayerLine Load *No Load Line SpeedDrum Capacity
lbfkgfkNft/minm/minftm
120009078.914.74.5206.1
218008168.016.35.04313.1
* Never exceed the Rated Capacity. Installation of a Rated Capacity Limiter is recommended.

FIRST LAYER PERFORMANCE - 12V
Line LoadCurrent Draw Line SpeedDuty Cycle
lbfkgfAmpsft/minm/minmin/10min
001314.74.5Continuous
4001813014.54.4Continuous
8003634813.94.26.7
12005446713.54.14.1
16007268713.04.02.9
200090710712.43.82.2

PERFORMANCE BY LAYER - 24V
Drum LayerLine Load *No Load Line SpeedDrum Capacity
lbfkgfkNft/minm/minftm
120009078.914.54.4206.1
218008168.016.14.94313.1
* Never exceed the Rated Capacity. Installation of a Rated Capacity Limiter is recommended.

FIRST LAYER PERFORMANCE - 24V
Line LoadCurrent Draw Line SpeedDuty Cycle
lbfkgfAmpsft/minm/minmin/10min
00614.54.4Continuous
4001811514.44.4Continuous
8003632514.04.3Continuous
12005443413.64.16.8
16007264413.24.04.6
20009075412.83.93.4