Industrial Hoists: DC4000


INDUSTRIAL HOIST DC4000

  • Powerful series-wound DC motor with robust sealing
  • Proven 3-stage all-metal gear train with permanent grease lubrication for years of trouble-free service
  • Large-frame design with a cast aluminum drum provides plenty of wire rope capacity
  • Automatic disc brake holds full rated load
  • Durable powder-coated finish stands up to the elements
DC4000 SPECS/PART NUMBERS
Part Number: 89833 (12V)
Part Number: 90124 (24V)
Rated Capacity: 4000 lbf (1814 kgf)
Drum Barrel Diameter: 6.40 in (163 mm)
Drum Flange Diameter: 10.0 in (254 mm)
Distance Between Flanges: 5.94 in (151 mm)
Recommended Maximum Wire Rope Diameter: 3/8 in (9.5mm)
Recommended Minimum Wire Rope Breaking Strength: 14400 lbf (6532 kgf)
Approximate Shipping Weight: 89.0 lb (40.4kg)
Duty Cycle (intermittent per SAE J706 section 6.2): N/A ft (N/A m)
Mounting Bolt Torque: 35 - 40 ft*lbf (47 - 54 N*m)
Maximum Layers of Wire Rope: 3
Gear Reduction: 315
Brake Type: Automatic Disc
Contactor/Remote Type: Not Included

ACCESSORIES
Control Pack-12V: PN 39602
Control Pack-24V: PN 39603
Contactor Only-12V (Standard bracket): PN 34969
Contactor Only-24V (Standard bracket): PN 34970
Contactor Only-12V (w/ bracket for cover): PN 34975
Contactor Only-24V (w/ bracket for cover): PN 34976
Contactor Cover (with remote plug): PN 36648
Contactor Cover (no plug): PN 35169
Remote Control Only: PN 88528

PERFORMANCE BY LAYER - 12V
Drum LayerLine Load *No Load Line SpeedDrum Capacity
lbfkgfkNft/minm/minftm
14000181417.827.58.4257.6
23601163316.030.59.35316.2
33275148614.633.610.28325.3
* Never exceed the Rated Capacity. Installation of a Rated Capacity Limiter is recommended.

FIRST LAYER PERFORMANCE - 12V
Line LoadCurrent Draw Line SpeedDuty Cycle
lbfkgfAmpsft/minm/minmin/10min
008927.58.46.5
100045413219.35.93.5
200090717615.04.62.5
3000136121512.63.81.9
4000181425710.83.31.5

PERFORMANCE BY LAYER - 24V
Drum LayerLine Load *No Load Line SpeedDrum Capacity
lbfkgfkNft/minm/minftm
14000181417.834.010.4257.6
23601163316.037.811.55316.2
33275148614.641.512.68325.3
* Never exceed the Rated Capacity. Installation of a Rated Capacity Limiter is recommended.

FIRST LAYER PERFORMANCE - 24V
Line LoadCurrent Draw Line SpeedDuty Cycle
lbfkgfAmpsft/minm/minmin/10min
007034.010.43.1
100045410027.18.32.7
200090713321.76.62.3
3000136116218.55.61.9
4000181419516.45.01.5