Tow Truck & Industrial DC Electric Winches: Series 9-S Spydura ProMax


Industrial Series 9-S Spydura ProMax

The Series 9-S winch is equipped with Warn Spydura ProMax synthetic rope and a drum and fairlead designed specifically for synthetic winch rope. Spydura ProMax synthetic rope features improved strength and ease of handling over conventional wire rope as well as full length rope cover for improved abrasion and UV resistance.

The winch also features a weatherproof industrial contactor and heavy duty remote control. The disc brake is designed to hold full rated load and the motor is protected by a thermal over-load switch. Designed to meet CE standards.

Remote Control Assembly-10m, Synthetic Rope, and Hawse Fairlead included

Industry-leading limited lifetime mechanical warranty; five (5) year electrical warranty

SPECS/PART NUMBERS
Part Number: 91033 12V
Rated Pulling Force: 9000 lbf (4082 kgf)
Drum Barrel Diameter: 4.0 in (102mm)
Drum Flange Diameter: 8.24 in (209 mm)
Distance Between Flanges: 9.7 in (246 mm)
Recommended Maximum Rope Diameter: 1/2 in (12.7 mm)
Recommended Min. Rope Breaking Strength: 16,000 lbf (7257 kgf)
Approximate Shipping Weight: 95.0 lb (43.1 kg)
Duty Cycle (intermittent per SAE J706 section 6.2): 75 ft (22.9 m)
Mounting Bolt Torque: 35 - 40 ft*lbf (47 - 54 N*m)
Maximum Layers of Rope: 4 (with 3/8" rope)
Gear Reduction: 199:1
Brake Type: Disk
Contactor / Remote Type: Industrial contactor with 33' (10m) heavy duty remote
Standards Compliance: CE Machinery Directive 98/37/EC and 2006/42/EC
CE Electromagnetic Compatibility 2004/108/EC
Warranty: Industry-leading limited lifetime mechanical warranty; five (5) year electrical warranty


ACCESSORIES
Kit-Synthetic Rope-Spydura ProMax-3/8" x 100ft: PN 91830
Kit-Fairlead-Hawse-12in-Syn Rope: PN 91690


PERFORMANCE DATA BY LAYER - 3/8" (9.5 mm) dia. rope
Drum Line Load * No Load Line Speed Drum Capacity
Layer lbfkgfkNft/minm/minftm
19000408240.026.07.9257.6
27518341033.431.19.55416.5
36455292828.736.311.18726.5
45655256525.241.412.612538.1

* Never exceed the Rated Pulling Force. Installation of a Rated Capacity Limiter is recommended.


FIRST LAYER PERFORMANCE
Line Load Current Draw Line Speed Duty Cycle
lbfkgfAmpsft/minm/minmin/10min
00101.026.07.94.1
1500680169.117.25.22.1
30001361233.012.83.91.4
45002041296.99.52.91.1
60002722362.95.51.70.9
75003402424.75.21.60.7
90004082486.02.90.90.6